Gauges (Dry, Preaction, and Deluge Systems)Valves, Valve Components, Trim Inspections – Sealed Control Valves – Master Pressure Reducing Fire Pump System – Casing Relief Valves – Pressure Relief Valves – Pump House, Heating Ventilating Louvers Backflow Prevention Assemblies – Reduced Pressure – Control Valves (locked/supervised) Standpipe – Sealed Control Valves – Gauges (Automatic Dry Standpipes)
Monthly
Portable Fire Extinguishers NFPA 10
Location Pressure Tamper Indicator, Hose/Nozzle Sign, Hanger, Hazard. Extinguishers Assessment, HMIS Label. Location in designated place. No obstruction to access or visibility. Operating instructions on nameplate legible and facing outward. Safety seals and tamper indicators not broken or missing. Fullness determined by weighing or “hefting”. Examination for obvious physical damage, corrosion, leakage or clogged nozzle. Pressure gauge reading or indicator in the operable range or position. Condition of tires, wheels, carriage, hose, and nozzle checked (for wheeled units) HMIS Label in place.
Automatic Fire Alarm NFPA 72 ULC S536
Control Equipment: Fire Alarm Systems Unmonitored for Alarm, Supervisory, and Trouble Signals
Fire Sprinkler NFPA 25
Gauges (wet, dry, preaction, and deluge systems) Valves, Valve Components, Trim Inspections – Locked/Supervised Control Valves – Alarm Valves (exterior bells) – Dry Pipe, Deluge, Preaction Valves Backflow Prevention Assemblies – Double Check Valves – Control Valves (locked/supervised) Standpipe – Control Valves (locked/supervised) – Gauges (Automatic Dry Standpipes Air Pressure Supervision) Private Fire Service Mains – Hose Houses
E-Lights/Exit Signs NFPA 101, 70
Function Test
Hood Suppression NFPA 17
Owners Inspection
Quarterly
Fire Sprinklers NFPA 25
Waterflow Alarm and Signaling Devices, including mechanical devices (i.e. water motor gongs) Valve Supervisory signal devices Supervisory signal devices (except valve supervisory switches) Gauges (Wet Pipe Systems) Fire Department Connections Pressure Reducing and Relief Valves Hydraulic Design Information Sign Backflow Prevention Assemblies
Hood Suppression NFPA 17
Owners Inspection
Semi-Annual
Hood Suppression NFPA 96, 17, 17A
Suppression System Fusible Link Replacement
Fire Sprinklers NFPA 25
Private Fire Service Mains – Monitor Nozzles
Semi-Annual (continued)
Automatic Fire Alarm NFPA 72, ULC S536
Control Equipment: Fire Alarm Systems Monitored for Alarm, Supervisory, and Trouble Signals – Fuses – Interfaced Equipment – Lamps and LEDs – Primary (main) Power Supply Control Equipment: Fire Alarm Systems Unmonitored for Alarm, Supervisory, and Trouble Signals – Nickel-Cadmium – Sealed Lead-Acid – Transient Suppressors Control Equipment: Fire Alarm Systems Unmonitored for Alarm, Supervisory, and Trouble Signals – Control Unit Trouble Signals – Emergency Voice/Alarm Communications Equipment – Remote Annunciators Batteries – Sealed Lead-Acid Initiating Devices – Air Sampling Smoke Detectors – Duct Smoke Detectors – Electromechanical Releasing Devices – Fire Extinguishing System(s) or Suppression System(s) Switches – Fire Alarm Boxes (Pull Stations) – Heat Detectors – Smoke Detectors – Interface Equipment – Alarm Notification Appliances – Supervised Supervising Station Fire Alarm Systems – Transmitters – DACT
All of monthly inspection, plus conductivity test (Carbon Dioxide), Determination of 6 year or Hydrotest, inspection of shell and nameplate. Hanger/seismic bracing
Automatic Fire Alarm NFPA 72, ULC S536
Control Equipment: Fire Alarm Systems Monitored for Alarm, Supervisory, and Trouble Signals ULC S536 – Fuses – Interfaced Equipment – Lamps and LEDs – Primary (main) Power Supply Control Equipment: Fire Alarm Systems Unmonitored for – Alarm, Supervisory, and Trouble Signals – Radiant Energy Fire Detectors – Supervisory Signal Devices – Waterflow Devices
Fire Sprinklers NFPA 25
Pipe and Fittings (from floor) Hangers/Seismic Bracing (from floor) Sprinklers (from floor) Spare Sprinklers Hydraulic Design Information Sign Information Sign Standpipe – Piping – Hose Racks – Hose Connections/Hose Valves – Hose/Hose Nozzles Valves, Valve Components, Trim Inspections – Interior Dry, Deluge, Preaction – Pressure Reducing Valves Private Fire Service Mains – Hydrants – Main Line Strainer
E-Lights/Exit Signs NFPA 101, 70
90 Minute drain test and inspection, verification of charge voltage, alignment of heads, hazard assessment, inspection sticker, required paperwork